Click On Picture
|
Un-Used Mcquay Indoor Water-Cooled Vertical Self-Contained Air Conditioning Unit - 40 Tons
|
|
Mfg: McQuay
|
Model: SWT040C27AL1MYY10101010YYYYMEYY21YYY
|
|
Stock No: JDWW041.
|
Serial No:
|
|
(40) Un-Used Mcquay Indoor Water-Cooled Vertical Self-Contained Air Conditioning Unit - 40 Tons.
Model: SWT040C27AL1MYY10101010YYYYMEYY21YYY. Installed but never commissioned at Global Crossing/ WorldCom’s headquarters building near Boston, Massachusetts. Mcquay self-contained units take up less floor space than standard chilled water air handling units and are being used successfully in TV studios, libraries, museums, schools and performing art centers where low noise levels are absolutely vital. They have demonstrated exceptionally low sound levels as verified in independent, laboratory tests. (ACN250).
|
|
Click here for Manual (2,988.3 KB) Click here for more information (840.0 KB)
|
|
|
Click On Picture
|
1994 Trane Heating and Cooling System- 6 Ton
|
|
Mfg: Trane
|
Model: YCD060C4L0BC
|
|
Stock No: ACEU854
|
Serial No: J411003670D
|
|
1994 Trane Heating and Cooling System- 6 Ton. Model YCD060C4L0BC. S/N J41100367D. Refrigerant: R-22. Compressor: 3 phase, 60 Hz, RLA 10.0, LRA 71, 460 V, permissible voltage 414-506, minimum circuit amps 16.3. Heating: natural gas. Input: 90,000 BTU/hr; output: 72,900 BTU/hr. Minimum input: 90,000 BTU/hr. (1) cooling fan on top.
|
|
Click here for more information (278.8 KB)
|
|
|
Click On Picture
|
Sterling (Westek) Industrial/Commercial Air Heater
|
|
Mfg: Sterling
|
Model: EIG-PV25A1CO1B61H30B3HIH2L3
|
|
Stock No: ACEU65
|
Serial No: A00062231001
|
|
Sterling (Westek) Industrial/Commercial Air Heater. Model EIG-PV25A1CO1B61H30B3HIH2L3. S/N A00062231001. Gas input: 250,000 BTU/hr; output: 200,000 BTU/hr; minimum input: 100,000 BTU/hr. Blower motor: 5 hp, 460 V, 3 phase, 60 Hz, requiring minimum circuit 10 amps. Motor full load rating: 7.6 amps. Unit air flow: 3000-5500 cfm @ 0-2 in W.C. Specially designed for operation at a temperature rise 20 to 60 °F. Overall dimensions: 98.5 in. L x 44 in. W x 44 in. H. This unit is an air heater for industrial or commercial use with ducts.
|
|
Click here for more information (174.3 KB)
|
|
|
Click On Picture
|
Sterling (Westek) Industrial/Commercial Air Heater
|
|
Mfg: Sterling
|
Model: EIG-PV25A1CO1B61H30B3HIH2L3
|
|
Stock No: ACEU65bb
|
Serial No: A00062231002
|
|
Sterling (Westek) Industrial/Commercial Air Heater. Model EIG-PV25A1CO1B61H30B3HIH2L3. S/N A00062231002. Gas input: 250,000 BTU/hr; output: 200,000 BTU/hr; minimum input: 100,000 BTU/hr. Blower motor: 5 hp, 460 V, 3 phase, 60 Hz requiring minimum circuit 10 amps. Motor full load rating 7.6 amps. Unit Air Flow: 3000-5500 cfm @ 0-2 in W.C. Specially designed for operation at a temperature rise 20 to 60 °F. Overall dimensions: 98.5 in. L x 44 in. W x 44 in. H. This unit is an air heater for industrial or commercial use with ducts.
|
|
Click here for more information (174.3 KB)
|
|
|
Click On Picture
|
Carrier Air Conditioning Unit- 8 Ton
|
|
Mfg: Carrier
|
Model: 50DA008400
|
|
Stock No: ACEU1010
|
Serial No: 8394539
|
|
Carrier Air Conditioning Unit- 8 Ton. Model: 50DA008400. S/N: 8394539. Refrigerant: R-22. Test pressure (hi/lo): 300/150 psig. Power supply: 208 V. Reciprocating Compressor, 208 V, 29.1 FLA, 60 Hz, 3 phase. GE Electrical Panel. Fan diameter: 25 in. Fan Motor, 1/2 hp, 208 V, 3.1 FLA, 60 Hz, single phase, 60 Hz, 3.1 FLA. Blower Fan Motor, 1/2 hp, 208 V, 5.0 FLA, 60 Hz, single phase. Unit is designed for installation outdoors on a concrete slab or rooftop. Overall dimensions: 72 in. L x 40 in. W x 33 in. H.
|
|
Click here for more information (189.8 KB)
|
|
|
Click On Picture
|
1989 Carrier Air Conditioner Model 50BT-004-540
|
|
Mfg: Carrier
|
Model: 50BT-004-540
|
|
Stock No: DBPF360.1a
|
Serial No: P985162
|
|
Carrier Air Conditioner Unit, Model 50BT-004-540, S/N P985162, Factory charged, refrigerant R 22. Compressor- 208-230 V, 3 phase, 60 Hz, RLA: 13, LRA: 87, Refrigerant: R22, 3.5 lbs. Test Pressure- 410 psi, 2827 Kpa, LP: 150 psi 1034 Kpa. Indoor Fan Motor- 208-230 V, 1 phase, 60 Hz, FLA: 3.3, 1/3 hp, Kw out: 0.28. Heater- 208-230 V, 3 phase, 60 Hz, Max volts: 253, Min volts: 187, Min Circuit Amps: 20.4, Max Overcurrent protective device amps 30 Fuse Only. Overall Dimensions: 45 in. L. x 24 in. W x 63 in. H
|
|
Click here for more information (242.1 KB)
|
|
|
Click On Picture
|
Carrier Air Conditioner with Water Cooled Condenser Model 50BT-004-540
|
|
Mfg: Carrier
|
Model: 50BT-004-540
|
|
Stock No: DBPF361.1a
|
Serial No: 8982860
|
|
Carrier Air Conditioner with Water Cooled Condenser. Model 50BT-004-540. S/N 8982860. Compressor 208/230 V AC, 3 phase, 60 Hz, Refrigeration system R22, 3.5 lbs. Fan Motor- 1/3 hp, 208/230 V, Kw out 0.248, 60 Hz, 1 phase, FLA 3.3, Permissible voltage at unit: 253 max, 187 min, circuit amps- 20 max, 4 min. Design test pressure- high 410 psi /2827 Kpa; low- 150 psi /1034 Kpa. Automatic Condensate Pump, Mfg. Hastell. Model KT-15-1UL. Inlets/Outlets (2) ˝ in. and (1) 3/8 in. 115 VAC, 1.3 amps, 60 Hz, 15 foot head. Has a 10 in. dia. blower fan. (1) 7 in. and (1) 3 in. pulley with 1/2 in. belt. Water Control Valve/ Mfg. Penn., S/N 8914, Prod # V46AB-1. Size 1/2 in., Fact Set 105, Range 70/260, Water Press 150 psig Max. Overall dimensions: 36 in. L x 21 in. W x 64 in. H. Inlets/Outlets (2) ˝ in. and (1) 3/8 in. 115 VAC, 1.3 amps, 60 Hz, 15 foot head. Has a 10 in. diameter blower fan. (1) 7 in. and (1) 3 in. pulley with 1/2 in. belt. Water Control Valve/ Mfg. Penn. Prod NO. V46AB-1. Size 1/2 in. Serial 8914, Fact Set 105, Range 70/260, Water Press 150 PSIG Max. The overall measurements are 36 in. L x 21 in. W x 64 in. H.
|
|
Click here for more information (213.3 KB)
|
|
|
Click On Picture
|
Carrier Evaporator - Water Circuit
|
|
Mfg: Carrier
|
Model:
|
|
Stock No: DBPF362.1a
|
Serial No: R983380
|
|
(2) Carrier Evaporator- Water Circuits. S/N R983380. Power Supply: 208-230 V, 3 phase, 60 Hz, permissible voltage at unit: 253 max, 187 min. Min circuit amps: 20 max, 4 min. Compressor RLA: 13.0, LRA: 87, Ref: R22, 3.55 lbs. Test pressure: hi/lo 1410/150 psi. Indoor fan: 208-230 V, 1 phase, 60 Hz, FLA: 3.3, 1/3 hp, KW Out 0.248. Overall dimensions: 43 in. L x 34 in. W x 75 in. H.
|
|
Click here for more information (197.2 KB)
|
|
|
Click On Picture
|
Trane Central Cooling Air Conditioner
|
|
Mfg: Trane
|
Model: SWUB-B306-E
|
|
Stock No: DBPF363.1a
|
Serial No: S87J 66449
|
|
(2) Trane Central Cooling Air Conditioners. Model SWUB-B306-E, Type 167-1202-08E, S/N S87J 66449. 208-230 V, Min./max. 187/254 V. Minimum circuit: 18 amps, Max fuse: 25 amps. Compressor: 3 phase, 60 Hz, RLA: 11.3, LRA: 66. Evaporator: 1 phase, 60 Hz, FLA: 4.0, 0.5 hp. (1) Refrigerant circuit. Factory charged with R22. R22 lbs/circuit: 3.9. Minimum test pressure (psig): hi/lo 425/225. Overall dimensions: 38 in. L x 23 in. W x 63 in. H.
|
|
Click here for more information (181.4 KB)
|
|
|
Click On Picture
|
Air Conditioner
|
|
Mfg: Not Specified
|
Model:
|
|
Stock No: SUBF391.4a
|
Serial No:
|
|
|
|
Click On Picture
|
Carrier AC Unit High Efficiency
|
|
Mfg: Carrier
|
Model: 50EE036
|
|
Stock No: ACEU857
|
Serial No:
|
|
Carrier AC Unit High Efficiency. Model 50EE036. Ref R22. Compressor Model 50EE 036. 1/2 hp fan, 208/230 volt, 1 phase, Comp amp 17.2. LRA 82 amp, IFM 4.2, OFM 1.5. Max fuse amp. 40.
|
|
|
|
|
Click On Picture
|
SOLD Heaters
|
|
Mfg: Not Specified
|
Model:
|
|
Stock No: ACEU04
|
Serial No:
|
|
Pallet of heaters, Gas Hanging Heaters SOLD
|
|
|
|
|
Click On Picture
|
SOLD Un-Used Airflow Company Computer Room Air Conditioning Unit-30 tons
|
|
Mfg: Airflow Company
|
Model: CCT-30G4-PC-UD
|
|
Stock No: JDWW011.
|
Serial No:
|
|
(6) Un-Used Airflow Company Room Air Conditioning Units - 30 Tons. Model: CCT-30G4-PC-UD. Refrigerant: R-22. Test pressure (hi/lo): 350/150 psig. Power supply: 460 V, 60 Hz, 3 phase. (2) Copeland Compliant Scroll Compressors, Model: ZR19M3-TWD-561, maximum operating pressure (hi/lo): 398.85/246.56 psi, power supply: 3500/2900 rpm, 460/380-420 V, 27.8/27.8 amps, 187/179-198 LRA, 60/50Hz, 3 phase. An up flow unit designed to reduce operating costs during mid to low ambient temperatures (71 – 77°F) by integrating an economizer coil into the glycol-cooled system. At a return glycol temperature of 45° F (7° C) published capacity is accomplished by the economizer coil, therefore compressor operation is typically not required. Designed to provide accurate temperature control of computer rooms, laboratories, and other environments requiring close tolerance controls. These units were installed but never commissioned at Global Crossing/ Worldcom’s headquarters building near Boston, Mass. Overall dimensions: 10 ft. 4 in. L x 34 in. W x 93 in. H. (ACN250). SOLD
|
|
Click here for additional information (827.0 KB) Click here for more information (1,919.0 KB)
|
|
|
|
|