 Genemco Sells Used Freon Split Systems and Rack Systems Manufactured by Carrier, Phoenix and York. 

Click On Picture

1993 Phoenix 75 Ton Rack System

1993 Phoenix 75 Ton Rack System
Mfg: Phoenix Model: PS622PMRA3S22
Stock No: 165.END1642 Serial No: PS3370E 083093
1993 Phoenix 75 Ton Rack System. Model: PS622PMRA3S22, S/N:PS3370E083093. (6) Copeland compressors: (2) 3 ton, (1) 10 ton, (1) 15 ton, (2) 22 ton. Chiller barrel: National Board No: 318892, Model: 10968. MAWP: 400 psi @ 150 °F; MDMT: -20 °F @ 400 psi. (2) Insulated suction accumulator tanks: 10 in. dia x 18 in. H. 1993 Discharge oil separator tank: Certified by Conyers Tank & Welding, S/N: 1672 . MAWP: 400 psi @ 150 °F, MDMT: -20 °F @ 400 psi. (13) Alco Evaporator Pressure Regulators. Overall dimensions: 18 ft. L x 3 ft. W x 7 ft . H. The rack if rated at -35 °F for a -10 °F freezer could go to -50 °F for a -35 °F blast. The suctions probably would tie together for the big blast coil. The unit would probably do 35 tons at that low condition. It looks to be in very good condition.

Click here for more information (398.1 KB)

Click On Picture

Carrier Air Cooled Condenser 40 Tons

SOLD Carrier Air Cooled Condenser 40 Tons
Mfg: Carrier Model: 09DK-044-600
Stock No: ACEU63b. Serial No: 3996F31844
Carrier Split System Air Cooled Condenser, Model 09DK-044-600, S/N 3996F31844 built in 1996. The unit operates on 460 volt, 3 phase, 60 HZ and has 3 outdoor fans 1 hp each with FLA = 3.3. The units permissible volts are 414-508 with a minimum circuit amps of 10.7. The controls power supply is 115 volt, single phase, 60 HZ, and 7 amps. Overall dimensions are 68 in. W x 52 in. H x 153 in. L.

SOLD

Click here for more information (302.2 KB)

Click On Picture

SOLD 2003 Carrier Split System Condensing Unit with Remote Air Handler- 25 Ton SOLD

SOLD 2003 Carrier Split System Condensing Unit with Remote Air Handler- 25 Ton
Mfg: Carrier Model: 30AKS028---601
Stock No: CAM202b.28 Serial No: 3303F49041
2003 Carrier Split System Condensing Unit with Remote Air Handler- 25 Ton. Model: 38KS028 601. S/N: 3303F49041. Outdoor use only. Refrigerant: R-22. Test pressure Hi/Lo (gage): 480/235 psi (3310/1620 kPa). Power supply electrical requirements for CKT1: 460 VAC (508 Vmax, 414 Vmin), 60 Hz, 3 phase. MCA: 60.9 amps. MOCP: 100 amps. (2) 29 in. dia. Fans with motors, 1.0 hp, 460 VAC, 3.2 FLA, 60 Hz, 3 phase. (2) Carlyle Semi-Hermetic Reciprocating Compressors, Model: 06E9265610G, S/N's: 31-3K-914. 3 cylinder. 400/460 volt, 3 ph, 50/60 hz, 223.o LRA. Inlets: (1) 1-1/2 in. dia. copper pipe. Outlets: (1) 1 in. dia. copper pipe. Overall dimensions: 10 ft. 8 in. L x 69 in. W x 55 in. H.

SOLD

Click here for more information (332.7 KB)

Click On Picture

1993 Phoenix Rack System 54 Ton

SOLD 1993 Phoenix Rack System 54 Ton
Mfg: Phoenix Model: PS322PLRA
Stock No: 115.END1641 Serial No: PS3370D083093
1993 Phoenix 54 Ton Rack System. Model: PS322PLRA, S/N:PS3370D083093. (3) Copeland compressors: (1) 10- ton, (2) 22- ton. Chiller barrel: National Board No: 318893, Model: 10968. MAWP: 400 psi @ 150 °F; MDMT: -20 °F @ 400 psi. (1) Insulated suction accumulator tank: 10 in. dia x 18 in. H. Discharge oil separator tank: Certified by Conyers Tank & Welding, S/N: 2179. MAWP: 400 psi @ 150 °F; MDMT: -20 °F @ 400 psi. (12) Alco Evaporator Pressure Regulators. Overall dimensions: 11 ft. L x 39 in. W x 87 in. H. The rack, if rated at -35 °F for a -10 °F freezer could go to -50 °F for a -35 °F blast. The unit would probably do 25 tons at that low condition.

SOLD

Click here for more information (279.2 KB)

Click Here if you don't see what you're looking for in our online catalog.